Circular Extensometer-3544 Model: JNJY4-3544


It is used to measure the pressure test of concrete and rock or the pressure test of other large samples. Can be shared with 3542RA axial extensometer at the same time.
The circumferential extensometer measures the circumferential change when the sample is compressed. Many researchers believe that this method is a more accurate method of determining radial strain.
It is suitable for use in containers and can work in oil at a temperature of 200 ° C and a pressure of 1350 bar.
The extensometer is mounted on the sample using a special high-precision roller chain. During the test, the diameter of the sample is enlarged, and the roller chain will expand the extensometer. The extensometer is self-held on the sample by means of a spring, and the roller chain can adjust the length according to the size of the sample. The mechanical adjustment method can be used to set the output value to zero. When the sample is broken, the safety separation device can protect the extensometer from damage.
Triaxial pressure sensors are usually used for testing rock samples. We also provide extensometers for use in containers and in oil environments, with pressures up to 1360 bar and temperatures up to 200 ° C. The extensometer can also be designed to fit a small inner diameter container.
For large radial strain measurement of large specimens, the 3544 extensometer is the best choice. For small strain measurements, the Model 3975 Extensometer is recommended.
Technical characteristics:
• 350 ohm full-bridge strain gauge design, compatible with almost all test systems • Strain measurement can be performed on many specimens by increasing or decreasing the chain length • The use of a rugged double-bending structure design greatly improves the performance of the extensometer • Random Equipped with advanced foam cushion box • The extensometer is clamped on the sample for measurement • Can be used together with the 3542RA type extensometer • Can be used in triaxial pressure sensors and technical specifications in high temperature and high pressure test environments:
Incentive: It is recommended to use 5-10VDC, the maximum is 12V DC / AC
Output: rated 2-4mV / V
Linearity: 0.25-0.30% of full scale
Temperature range: Standard type (-ST) is -40 ℃ - + 100 ℃
Connection: 2.5m
Optional parts:
Connecting piece that can be connected to any brand test equipment Shunt calibration module Horizontal, vertical or variable direction extensometer ordering information >>>>>
Unless otherwise specified, the diameter ranges, circumference measurement ranges, and temperature ranges listed below can be arbitrarily combined.