Technical Article: Precautions for Safe Operation of Centrifuges

Notes on centrifugation

High-speed and ultra-speed centrifuges are important precision equipment for biochemical experiment teaching and biochemical research. Due to their high rotation speed and large centrifugal force, improper use or lack of regular maintenance and repair may cause serious accidents. Therefore, you must use a centrifuge Strictly follow the operating regulations.

1. When using various centrifuges, the centrifuge tube and its contents must be precisely balanced on the balance beforehand. The weight difference during balancing must not exceed the range specified in the manual of each centrifuge. Each centrifuge has a different rotor. The respective allowable difference, the singular tube must not be loaded in the rotor. When the rotor is only partially loaded, the tubes must be placed symmetrically with each other in order to distribute the load evenly around the rotor.

2. When loading the solution, it should be carried out according to the specific operating instructions of various centrifuges. According to the nature and volume of the liquid to be centrifuged, select the appropriate centrifuge tube. Some centrifuge tubes have no caps, and the liquid should not be filled too much to prevent After being thrown out, the rotating head is unbalanced, rusted or corroded, and the centrifuge tube of the preparative ultracentrifuge often requires that the liquid must be filled to avoid the deformation of the upper part of the plastic centrifuge tube during centrifugation. After each use, the rotor must be carefully checked, cleaned, and dried in time. The rotor is a key part of the centrifuge. Be careful when moving it. Do not collide with it to avoid scars. When the rotor is not used for a long time, Coated with a layer of polished wax protection, it is strictly prohibited to use centrifuge tubes with significant deformation, damage or aging.

3. To centrifuge at a temperature below room temperature. The rotor should be placed in the refrigerator or placed in the rotor chamber of the centrifuge for pre-cooling before use.

4. Do not leave at will during the centrifugation process. Observe whether the instrument on the centrifuge is working properly at any time. If there is any abnormal sound, immediately stop the machine to check and eliminate the fault in time.

5. Each rotor has its maximum allowable rotation speed and cumulative time limit for use. Please refer to the instruction manual when using the rotor, and do not use it too fast. Each rotor must have a use file that records the cumulative use time. If it exceeds the maximum use limit of the rotor, it must be used at a reduced speed. Notes on centrifugation

High-speed and ultra-speed centrifuges are important precision equipment for biochemical experiment teaching and biochemical research. Due to their high rotation speed and large centrifugal force, improper use or lack of regular maintenance and repair may cause serious accidents. Therefore, you must use a centrifuge Strictly follow the operating regulations.

1. When using various centrifuges, the centrifuge tube and its contents must be precisely balanced on the balance beforehand. The weight difference during balancing must not exceed the range specified in the manual of each centrifuge. Each centrifuge has a different rotor. The respective allowable difference, the singular tube must not be loaded in the rotor. When the rotor is only partially loaded, the tubes must be placed symmetrically with each other in order to distribute the load evenly around the rotor.

2. When loading the solution, it should be carried out according to the specific operating instructions of various centrifuges. According to the nature and volume of the liquid to be centrifuged, select the appropriate centrifuge tube. Some centrifuge tubes have no caps, and the liquid should not be filled too much to prevent the centrifuge. After being thrown out, the rotating head is unbalanced, rusted or corroded, and the centrifuge tube of the preparative ultracentrifuge often requires that the liquid must be filled to avoid the deformation of the upper part of the plastic centrifuge tube during centrifugation. After each use, the rotor must be carefully checked, cleaned, and dried in time. The rotor is a key part of the centrifuge. Be careful when moving it. Do not collide with it to avoid scars. When the rotor is not used for a long time, Coated with a layer of polished wax protection, it is strictly prohibited to use centrifuge tubes with significant deformation, damage or aging.

3. To centrifuge at a temperature below room temperature. The rotor should be placed in the refrigerator or placed in the rotor chamber of the centrifuge for pre-cooling before use.

4. Do not leave at will during the centrifugation process. Observe whether the instrument on the centrifuge is working properly at any time. If there is any abnormal sound, immediately stop the machine to check and eliminate the fault in time.

5. Each rotor has its maximum allowable rotation speed and cumulative time limit for use. Please refer to the instruction manual when using the rotor, and do not use it too fast. Each rotor must have a use file that records the cumulative use time. If it exceeds the maximum use limit of the rotor, it must be used at a reduced speed. (Organized by China Educational Equipment Purchasing Network)

welcome to our Cat Scratching Pads pages.We can design any kinds of Pet Supplies according to your opinion.We also can return your imagination into reality.

Good Quality, good service, good price and good credit are our business principle. Base on that, our pet supplies have been sold to North American, European, Asia and Australia .Moreover, we have enjoyed a good reputation in these marketing. For developing more business with our old and new customers, we have established our own sourcing and design department for new pet items in every day.